| Specifications |
| Ranges: | 0-50 to 0-2,000 ppb, operator selectable; Dual ranges and auto-ranging supported |
| Units: | ppb, ppm, µg/m3, mg/g3 operator selectable |
| Zero noise: | < 0.5 ppb (RMS) |
| Span noise: | < 0.5% of reading (RMS) above 50 ppb |
| Lower Detectable Limit (LDL): | 1 ppb |
| Zero drift: | 0.5 ppb/24 hours, < 1.0 ppb/7 days |
| Span drift: | < 1% of reading/24 hours, < 2% of reading/7 days |
| Lag time: | 40 seconds |
| Rise and Fall Time: | 90% in 120 seconds |
| Linearity: | < 1% of full scale |
| Precision: | 0.5% of reading |
| Sample Flow Rate: | 1000 cc/min ±10% |
| Operating Temperature Range: | 10 - 30° C |
| Dimensions (HxWxD): | 7” (178 mm) x 17” (432 mm) x 23.5” (597 mm) |
| Weight: | Analyzer - 43 lbs (21 kg) |
| Power: | 100V 50/60 Hz, 115V 60Hz, 220V 50/60Hz, 230V 50Hz, 240V 50Hz |
| Analog outputs: | 10V, 5V, 1V, 0.1V, selectable |
| Recorder Offset: | ±10% |
| Serial Outputs: | RS-232 (DB-9) Connector |
| Status (Digital): | 12 outputs from optoisolator, included with standard configuration |
| Current Output: | 0-20 mA or 4-20 mA isolated outputs (optional) |
| Approvals: | CE |